布线发展史

Let’s All Calibrate and Have a Good Time!

Just like those who drive around long after the engine service indicator lights up on the dashboard, there are folks out there who have likely been putting off getting their t

Calibrate Testing by Network Technicians

ester calibrated despite the email or LinkWare Live notification from Fluke Networks.

2018 年 4 月 4 日

Too Soon to Say Goodbye? It’s All Relative…

You might remember that just about three years ago, the DTX CableAnalyzer™ was officially retired. Since its discontinuation, Fluke Networks has continued to offer technical support, repair and calibration for this tester that was once touted as the ultimate time saver and brought testing to a whole new level when it was introduced in 2004.

2018 年 3 月 28 日

The OM Mantra

Adopted by TIA, the nomenclature for multimode fiber found in the ISO/IEC 11801 standard includes the prefix “OM.”OM Mantra

Rather than the spiritual mantra you hear in yoga class, most sources in our industry state that the acronym OM comes from “optical multimode” which seems rather obvious. But when it comes to the various nuances of each type of OM, the differences aren’t quite as obvious.

2018 年 3 月 14 日

OTDR: Your Ultimate Troubleshooter

So you’ve finished your fiber cable installation and are now on to the task of certifying the cable plant using an optical loss test set (OLTS) – it’s the tool you need for Tier 1 certification and theTesting with OptiFiber Pro OTDR most accurate for measuring loss to ensure application support.

2018 年 2 月 28 日

Is Your Fiber End Face Up to Scratch?

While it seems we can never hammer home enough the need to properly clean and inspect fiber end-faces since contamination remains the number one cause of fiber link failures, have you ever thought about what exactly you are cleaning and inspecting?

2018 年 2 月 21 日

BICSI Wrap Up: Top 3 Questions Asked

It’s always interesting at trade shows to learn what’s on the minds of end users, designers and technicians alike when it comes to testing. And this year’s BICSI Winter Conference was no different.

2018 年 2 月 14 日

Know Your SYSTIMAX Loss Target Before You Fail!

We’ve covered fiber insertion loss in plenty of past blogs, so by now we hope that you know it’s the amount of signal loss that occurs as the signal travels along a cable link. We also hope you know that insertion loss is directly related to the length of the cable—the longer the cable, the greater the loss—and that any connection point along the way (connectors, splices, splitters, etc.) also adds to the loss. 

2018 年 2 月 7 日

Gain 3 CECs at Our BICSI Pre-Conference Seminar on Testing High Speed Fiber Links

High speed applications are driving the deployment of multifiber MPO/MTP architectures in the data center, and it’s not just cloud and hyperscale data centers that are deploying these solutions. As the de facto interface for 40 Gig and 100 Gig switch-to-switch backbone data center applications that use parallel optics, MPO/MTP links are rapidly becoming commonplace in today’s enterprise data centers.

2018 年 1 月 31 日

2018 - Smack-Dab in the IoT Revolution

At this time of year, every industry tends to reflect on the past twelve months and make predictions about what 2018 will bring – it’s just what we do. So why should this year be any different?Year 2018 Versiv Kit Configuration Instructions

2018 年 1 月 3 日